AS - Anti-Static PTFE Liner

9995

99

149

与供应商联系

产品描述

产品目录

产品视频

Purpose
Bioflex Ultra AS is an essential requirement in applications where there is the risk of an electrostatic charge build-up on the inside surface of the PTFE tube which may then discharge through the tube wall. Media passing through which create such a risk are fluids which have a Conductance of less than 108 S/m (Siemens per Metre), or 104 pS/m such as fuels, solvents, freons, some WFI (ultra-pure “Water for Injection”) and non-polar organics which are being transferred at a medium to high flow velocity.
All twin or multi phase media, and any non-mixing media, such as powder in air, or water droplets in steam, in gases or in oil, also colloidal fluids constitute a particular hazard for static charge generation, and always require grade AS.
If in doubt, either order AS grade, or consult Aflex Hose.
Design & Approvals
Bioflex Ultra AS is an anti-static PTFE liner manufactured from FDA 21 CFR 177.1550 approved PTFE, mixed with less than 2.5% of ‘high purity’ Carbon Black material to FDA requirement 21 CFR 178.3297. Bioflex Ultra AS grade also meets the requirements of EC Directive 2007/19/EC. The carbon is encapsulated by the PTFE, and in normal, non-abrasive applications will not come loose to contaminate any fluid passing through.
Bioflex Ultra AS also conforms to USP Class VI, at 37˚C (99˚F), 70˚C (158˚F) and at 121˚C (250˚F) - see Quality Assurance & Certification.
Antistatic Hose Assemblies
When “AS” (Antistatic) grade hose is specified, then the hose or hose assembly supplied will be tested in accordance with EN ISO 8031 and meet the Antistatic requirements of EN ISO 8031 Annex A. This requires, for an antistatic liner or antistatic cover, that the resistance between an appropriately placed foam electrode and a metallic end fitting will be between 103 to 108 ohms per assembly. For hose assemblies which meet these requirements an appropriate Grade “Ω” marking can be applied in accordance with EN ISO 8031 Annex A if requested.
Note: When in service, at least one end fitting must be connected to earth, to permit dissipation of the static charge from the end fitting.