Steam Boilers EX Series Models

695

6

9

与供应商联系

产品描述

产品目录

产品视频

EX-100 SGO
EX Gas/Oil Series – High Pressure Steam Boiler 
100HP
EX-150 SGO
EX Gas/Oil Series – High Pressure Steam Boiler 
150HP
EX-200 SGO
EX Gas/Oil Series – High Pressure Steam Boiler 
200HP
EX-250 SGO
EX Gas/Oil Series – High Pressure Steam Boiler 
250HP
EX-300 SGO
EX Gas/Oil Series – High Pressure Steam Boiler 
300HP

Miura is known world-wide for our commitment to protecting the environment and our innovative and efficient boiler designs. Our EX Gas/Oil Series High Pressure Steam Boiler is the most versatile industrial steam boiler in the world. The EX design minimizes carryover and produces dry 99+% saturated steam in less than 5 minutes from a cold start. Faster start-up means less fuel used, greater savings, and more responsible use of precious natural resources.
Dual fuel fired: Natural Gas, Propane or #2 Fuel Oil
High pressure options available (300 MAWP, 250 MAWP or 170 MAWP)
Hot water boilers are available depending on models (refer to the catalog for the hot water boilers for details)
NOx rating is available as low as 30ppm depending on model

EX Series Model Design
The MIURA EX Series design consists of rows of vertical tubes sandwiched between two rectangular headers. Both headers are encased in a castable refractory with only the tubes exposed to flame and/or combustion gases. The upper header is attached to the lower header only by the tubes. As the tubes expand and contract, the headers float up and down accordingly.
This ’floating header’ concept greatly reduces stress and allows for the use of cold feedwater without the fear of significant thermal shock. The ’leaky tube’ problems associated with firetube and bent watertube designs have been eliminated.

Ultra Compact Design Saves Space and Costs
Miura's EX Series boilers occupy 33% less floor space than typical firetubes, and do not require tube pull space. Compact design means much smaller radiation losses and larger fuel savings.

Full Steam Output In Less Than 5 Minutes
Floating headers mean fast start-up. MIURA boilers produce fast steam in less than 5 minutes from a cold start-up. Standard firetubes require 1 to 1.5 hour start-up times. Miura’s unique design yields significant time and fuel savings.

Dry Steam
The MIURA EX design minimizes carryover and produces dry 99+% saturated steam through a 3-stage process:
Initial separation in the tubes
Second separation in the upper header and baffle plate
Final separation in the cyclone separator

Early Warning Scale Monitor
Scale is a problem all boilers have to deal with. Scale forms when boiler feedwater is not properly treated. Advanced scale formation acts as an insulator; only an eggshell thickness of scale results in a 10% efficiency loss, higher fuel bills and possible damage to the boiler system.
As standard equipment, all Miura EX models are equipped with a thermocouple attached directly to a tube. Should scale begin to form, the Miura boiler will alert the operator - allowing the operator to trace and repair the source of the water hardness. The scale can be removed to restore the boiler to its original efficiencies - saving tens of thousands of dollars in wasted fuel and repair bills.

Unbeatable In-Service Efficiencies
Miura’s computer-aided design results in optimal heating surface transfer with minimal water content for fuel-to-steam efficiencies of 85%. Typical firetube designs can deliver up to 83% fuel-to-steam efficiencies. However, in actual use, MIURA averages 10 to 40% fuel savings over standard firetube designs. How does a 2% difference in fuel-to-steam efficiencies translate into a 10 to 40% ACTUAL FUEL SAVINGS? Contact your local Miura representative for details.