56 Advanced Dual Input Analyzer

8760

87

130

与供应商联系

产品描述

产品目录

产品视频

High Resolution full-color screen: easily viewed process measurements
and on-screen data trend graphs
User help screens: detailed instructions and troubleshooting in
multiple languages
Data logger and event logger: download process data and alarm
conditions with time and date stamps via USB 2.0 data port
Control - PID and time proportional capabilities. Also includes synchronize interval timers and four special application functions
Digital Communications: HART® and Profibus® DP communications with full features and functions


Features & Benefits
The 56 is a line powered analyzer offering single or dual sensor input with an unrestricted choice of dual measurement combinations. The 56 measures pH, ORP, ISE, Conductivity, Chlorine, Dissolved and Gaseous Oxygen, Dissolved Ozone, Temperature, Turbidity, or Flow and will accept 4-20mA current input. The device is offered in 24VDC or 115/230 auto-switching AC. HART digital communications is a standard feature.

The unit supports SMART pH sensors by Rosemount Analytical. All configurations meet UL approval requirements for Ordinary Locations.

Special Features

Full color display: High resolution full-color display (480 x 272 pixels)
Local Operator Interface: Computer-like screens allow easy navigation for local configuration and routine calibration.
Diagnostics: Continuous monitoring of the analyzer and the sensor loop(s) for fault and warning conditions.
Data Logger: Records data from both channels and temperature every 30 seconds for 30 days
Event Logger Audit Trail: Up to 300 significant events are recorded
PID Control: Proportional, Integral and Derivative settings allow up to four analog current outputs to adjust a control device that has continuous adjustability
Real-time Clock: Applies time/data stamps to all process data and events
USB Data Port: Allows local transfer of all process data and events for evaluation on a computer
Timer Functions: Time-proportional control, interval timers and four special application timers: bleed and feed, day and time interval timers, delay timer and a flow totalizer.
Security Access: Two levels of password access
Diagnostics: Continuously monitors and records the analyze and sensor(s) for fault conditions
Wireless-ready: HART versions enable wireless transmissions of process variables and diagnostics from hard-to-reach locations with the Wireless THUM Adaptor.



Specifications
Case: Polycarbonate
Dimensions: 6.2 x 6.2 x 5.2 in. (157 x 157 x 132mm)
Conduit openings: Accepts (6) PG13.5 or 1/2 in. conduit fittings
Display: Large 3.75 x 2.2 in. (95.3 x 55.9mm) high resolution
color LCD displays large process variables and user-definable display of diagnostic parameters. Calibration, programming and information screens display clear, easy-to-read characters. The color display is back-lit and backlighting intensity is user adjustable. Measurement character height: (.5") 13mm. Main display can be customized to meet user requirements.
Ambient temperature and humidity: -10 to 60°C, (14 to 140°F) RH 5 to 95% (non-condensing). For Turbidity only: 0 to 55°C (32 to 131°F). RH 5 to 95% (non-condensing).
Note: Some degradation in display response or performance
may occur below -5°C (23°F) and above 55°C (131°F). Above 60°C, the following components will progressively and automatically shut down: display, USB communications port, current outputs, alarm relays, main circuit board.
WARNING: Always remove USB memory device if ambient temp exceeds 60°C. Do not access USB port if combustible atmosphere is present.
Storage temperature: -20 to 60°C, (-4 to 140°F)
Power:
Code -02: 20 to 30 VDC. 20 W
Code –03: 85 to 264 VAC, 47.5 to 65.0 Hz, 20 W
Real time clock back-up: 24 hours.
RFI/EMI: – EN-61326
LVD: – EN-61010-1
Model 56 Hazardous Location Approvals
Options for CSA: -02, 03, 20, 21, 22, 24, 25, 26, 27, 30, 31, 32,
34, 35, 36, 37, 38, HT and DP.
Class I, Division 2, Groups A, B, C, & D
Class Il, Division 2, Groups E, F, & G
Class Ill T4A Tamb= 50°C
Evaluated to the ANSI/UL Standards. The ‘C’ and ‘US’ indicators
adjacent to the CSA Mark signify that the product has been evaluated to the applicable CSA and ANSI/UL Standards, for use in Canada and the U.S. respectively
Options for FM: -02, 03, 20, 21, 22, 23, 24, 25, 26, 27, 30, 31, 32, 33, 34, 35, 36, 37, 38, HT and DP.
Class I, Division 2, Groups A, B, C, & D
Class Il & lll, Division 2, Groups E, F, & G
T4 Tamp = -10 deg C to 60 deg C.
Ordinary Locations (only with -UL ordering option):
Options for UL: -02, 03, 20, 21, 22, 24, 25, 26, 27, 30, 31, 32,
34, 35, 36, 37, 38, HT and DP.
Altitude: for use up to 2000 meter (6562 ft.)
Pollution Degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
Input: One or two isolated sensor inputs. Measurement choices
of pH/ORP, resistivity/conductivity/TDS, % concentration, ratio
conductivity, total and free chlorine, monochloramine, dissolved
oxygen, dissolved ozone, turbidity, pulse flow, temperature and
raw 4-20mA input. For contacting conductivity measurements,
temperature element must be a Pt1000 RTD. For other measurements (except ORP, flow and turbidity), use either a PT100 RTD, PT1000 RTD, or 22k NTC (D.O. only).
Outputs: Four actively powered 4-20 mA or 0-20 mA isolated current outputs. Fully scalable. Max Load: 550 Ohms. Outputs can be
programmed for PID control. Output dampening can be enabled
with time constants from 0 to 999 seconds. HART digital communications which is superimposed on output 1 is standard on all
units (option code –HT).
Alarms: Four alarm relays for process measurement(s) or
temperature. Any relay can be programmed for any measurement,
timer, TPC or fault alarm operation, instead of a process alarm. When selected, a fault alarm will activate the relay when a sensor or analyzer fault occurs. Each relay can be configured independently. Alarm logic (high or low activation or USP) and deadbands are user-programmable.
Relays: Form C, SPDT, epoxy sealed
Inductive load: 1/8 HP motor (max.), 115/240 VAC
Terminal Connections Rating
Power connector (-02 24VDC power supply and -03 85-264VAC
power supply): 24-12 AWG wire size.
Signal board terminal blocks: 26-16 AWG wire size.
Current output connectors: 26-16 AWG wire size.
Alarm relay terminal blocks: 24-12 AWG wire size.
Weight/Shipping Weight: (rounded up to nearest lb or nearest
0.5 kg): 3 lbs/4 lbs (1.5 kg/2.0 kg)


Applications
pH Measurement in Deinking Mills (Secondary Fiber)
Sulfuric Acid Manufacturing
pH Measurement in Corn Wet Milling
  • LIQ-ANO-Power-Monitoring-Steam-Purity-1.pdf
    2403 KB
    美国
  • LIQ-ANO-Chemical-pH-Measurement-Chlor-Alkali-Plants.pdf
    1891 KB
    美国
  • LIQ_ADS_Water_Bottled_Liquid_Analytical_Solutions.pdf
    220 KB
    美国
  • LIQ_PDS_ABR_56_Chlorine_Turbidity.pdf
    1240 KB
    美国
  • Liq_ProdData_71-56.pdf
    2036 KB
    美国
  • Liq_ProdData_71A-56.pdf
    219 KB
    美国
  • LIQ-ANO-Power-Desulfurization.pdf
    1111 KB
    美国
  • LIQ_ADS_Water_Bottled_Liquid_Analytical_Solutions_EU.pdf
    557 KB
    美国
  • 56 Loop Calibration Made Easy
所有产品
Other
全球领先的卫生级工业在线展会
登录
新访客? 注册
一旦注册,意味着您同意遵守我们的 使用条款, 隐私条款,以及 网站cookie条款
已经有账户? 请直接登录